<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-22T20:11:16Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/4380" metadataPrefix="qdc">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/4380</identifier><datestamp>2022-04-29T12:02:47Z</datestamp><setSpec>com_10259_4376</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_4377</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
<dc:title>Acetylcholinesterase Inhibition-Based Biosensor for Aluminum(III) Chronoamperometric Determination in Aqueous Media</dc:title>
<dc:title>Artículo</dc:title>
<dc:creator>Barquero Quirós, Miriam</dc:creator>
<dc:creator>Domínguez Renedo, Olga</dc:creator>
<dc:creator>Alonso Lomillo, Mª Asunción</dc:creator>
<dc:creator>Arcos Martínez, Julia</dc:creator>
<dc:subject>acetylcholinesterase</dc:subject>
<dc:subject>biosensor</dc:subject>
<dc:subject>aluminum</dc:subject>
<dc:subject>acetylthiocholine iodide</dc:subject>
<dc:subject>screen-printed electrodes</dc:subject>
<dc:subject>gold nanoparticles</dc:subject>
<dcterms:abstract>A novel amperometric biosensor for the determination of Al(III) based on the inhibition of the enzyme acetylcholinesterase has been developed. The immobilization of the enzyme was performed on screen-printed carbon electrodes modified with gold nanoparticles. The oxidation signal of acetylthiocholine iodide enzyme substrate was affected by the presence of Al(III) ions leading to a decrease in the amperometric current. The developed system has a detection limit of 2.1 ± 0.1 μM for Al(III). The reproducibility of the method is 8.1% (n = 4). Main interferences include Mo(VI), W(VI) and Hg(II) ions. The developed method was successfully applied to the determination of Al(III) in spiked tap water . The analysis of a certified standard reference material was also carried out. Both results agree with the certified values considering the respective associated uncertainties.</dcterms:abstract>
<dcterms:dateAccepted>2017-03-20T08:50:47Z</dcterms:dateAccepted>
<dcterms:available>2017-03-20T08:50:47Z</dcterms:available>
<dcterms:created>2017-03-20T08:50:47Z</dcterms:created>
<dcterms:issued>2014-05</dcterms:issued>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>http://hdl.handle.net/10259/4380</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>Sensors, 2014, V. 14, n. 5, p. 8203-8216</dc:relation>
<dc:relation>http://dx.doi.org/10.3390/s140508203</dc:relation>
<dc:rights>http://creativecommons.org/licenses/by/3.0/</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:rights>Attribution 3.0 Unported</dc:rights>
<dc:publisher>MDPI</dc:publisher>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>