<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-31T10:12:03Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/5347" metadataPrefix="rdf">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/5347</identifier><datestamp>2022-04-08T10:31:37Z</datestamp><setSpec>com_10259_4376</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_4377</setSpec></header><metadata><rdf:RDF xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
<ow:Publication rdf:about="oai:riubu.ubu.es:10259/5347">
<dc:title>Development of a selective chloride sensing platform using a screen-printed platinum electrode</dc:title>
<dc:creator>Cunha Silva, Hugo</dc:creator>
<dc:creator>Arcos Martínez, Julia</dc:creator>
<dc:subject>Chloride</dc:subject>
<dc:subject>Platinum electrode surface</dc:subject>
<dc:subject>Cathodic stripping voltammetry</dc:subject>
<dc:subject>Screen-printed electrode</dc:subject>
<dc:subject>Flexible sensor</dc:subject>
<dc:description>A new and selective voltammetric method for chloride determination is proposed, based on platinum and chloride interactions. A screen-printed platinum electrode (SPPtE) functions as a sensing platform, which promotes the formation of chloro-adsorbed species on the electrode surface, acting as an effective means of anion-determination in several matrices. The pretreatment of the SPPtE and careful control of the cathodic stripping voltammetric parameters yielded a well-defined electrochemical signal. This cathodic peak was due to the adsorption of chlorine, which had previously been oxidized from chloride anions in the initial anodic deposition step. It offers a simple, low-cost, fast, reproducible (RSD &lt; 6%) and precise method for selective chloride determination, with limit of detection of 0.76 mM, and a sensitivity of − 24.147 µA mM −1 for a broad determination range of up to 150 mM. Chloride determination was correctly performed with single drops of environmental, pharmaceutical and food samples. In addition, the sensor was successfully adapted as a flexible screen-printed platinum electrode sensor using Gore-Tex® as support for printing.</dc:description>
<dc:date>2020-06-18T08:19:40Z</dc:date>
<dc:date>2020-06-18T08:19:40Z</dc:date>
<dc:date>2019-04</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>0039-9140</dc:identifier>
<dc:identifier>http://hdl.handle.net/10259/5347</dc:identifier>
<dc:identifier>10.1016/j.talanta.2018.12.008</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>Talanta. 2019, V. 195, p. 771-777</dc:relation>
<dc:relation>https://doi.org/10.1016/j.talanta.2018.12.008</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/MICINN/TEC20013-40561-P</dc:relation>
<dc:relation>info:eu-repo/grantAgreement/MINECO/MUSSEL RTC-2015-4077-2</dc:relation>
<dc:rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:rights>Attribution-NonCommercial-NoDerivatives 4.0 Internacional</dc:rights>
<dc:publisher>Elsevier</dc:publisher>
</ow:Publication>
</rdf:RDF></metadata></record></GetRecord></OAI-PMH>