<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-22T20:18:37Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/5632" metadataPrefix="marc">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/5632</identifier><datestamp>2022-11-23T01:05:26Z</datestamp><setSpec>com_10259_4249</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_4250</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield tag="042" ind1=" " ind2=" ">
<subfield code="a">dc</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Ortiz Fernández, Mª Cruz</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Sarabia Peinador, Luis Antonio</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Herrero Gutiérrez, Ana</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Reguera Alonso, Celia</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Sanllorente Méndez, Silvia</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Arce Antón, Mar</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Valencia García, Olga</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Ruiz Miguel, Santiago</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Sánchez Pastor, Mª Sagrario</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2021</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Inside the framework of Analytical Quality by Design, a model-based approach has been developed and used to identify operating conditions (control method parameters) related to the composition and flow rate of the mobile phase for a liquid chromatographic determination with preset quality characteristics.&#xd;
&#xd;
The approach starts by defining these desired characteristics of the intended chromatogram (proper resolution for consecutive peaks and short time of analysis) and then looking for the needed control method parameters via inversion of a Partial Least Squares (PLS) prediction model.&#xd;
&#xd;
The procedure has been applied to the determination of eight triazines (simazine, simetryn, atrazine, ametryn, propazine, terbuthylazine, prometryn and terbutryn) in surface waters by means of SPE-HPLC-DAD. These triazines either are forbidden or have a maximum allowable limit due to their potential toxicity.&#xd;
&#xd;
The experimental verification of the selected parameters showed that the experimental results were significantly equal to those predicted. Besides, the validation of the developed method allowed concluding that accuracy was fulfilled for the eight triazines and there was not bias. With a probability of false positive equal to 0.05, CCβ was less than 3 µg L−1 for every triazine, except for simazine and terbutryn, which was less than 6 µg L−1 being the probability of false negative less than 10-6.&#xd;
&#xd;
No triazine was found, above their maximum allowable concentration, in any of the samples of surface water picked at fifteen different locations, mostly from streams and the Arlanzón river, near Burgos (Spain).</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">0026-265X</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">http://hdl.handle.net/10259/5632</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">10.1016/j.microc.2021.105971</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">PLS inversion</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">HPLC-DAD</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Product design</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Analytical Quality by Design</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Triazines</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Surface water</subfield>
</datafield>
<datafield tag="245" ind1="0" ind2="0">
<subfield code="a">Partial least squares model inversion in the chromatographic determination of triazines in water</subfield>
</datafield>
</record></metadata></record></GetRecord></OAI-PMH>