<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-22T15:21:18Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/9303" metadataPrefix="marc">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/9303</identifier><datestamp>2024-06-21T00:05:18Z</datestamp><setSpec>com_10259_4393</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>com_10259_9301</setSpec><setSpec>com_10259_9300</setSpec><setSpec>com_10259.4_106</setSpec><setSpec>col_10259_4394</setSpec><setSpec>col_10259_9302</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield tag="042" ind1=" " ind2=" ">
<subfield code="a">dc</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Granados López, Diego</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Gatt, Damien</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Yousif, Charles</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Diez Mediavilla, Montserrat</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Alonso Tristán, Cristina</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2023-12</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The 2018/844 Energy Performance of Buildings Directive (EU) has widened the scope of appropriate design of buildings from a pure energy performance and carbon emissions perspective to a wider scope that includes indoor comfort, and indoor air quality among others. To this effect, external parameters, especially solar energy, have a strong impact on the energy performance of buildings in Mediterranean regions, which requires careful consideration when it comes to benefiting from natural lighting while avoiding solar overheating. This paper addresses the considerations of natural lighting in the deep renovation of a housing block in the Mediterranean climate of the Republic of Malta, comparing some of the usual illuminance ranges to achieve optimal conditions based on international recommendations. DesignBuilder v7.0.0.102 has been the selected software to model the building that has been calibrated through experimental measurements. The model enabled the natural lighting conditions in the building evaluated and the effectiveness of suggested improvements to be determined. Results pointed out that the building under study satisfies the international standards about the prevention of visual discomfort only. Increasing the size of windows in identified zones, especially the first floor, was found to help improve other natural lighting characteristics. One of the proposed designs (Model 6) that replaces single-glazed with double-glazed windows that include an external spectrally-selective coating would significantly improve access to natural light bringing the building closer to the recommended levels of Annual Sunlight Exposure and reducing artificial lighting usage by up to five times. The relocation of room spaces could also reduce the use of artificial lighting.</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">2352-4847</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">http://hdl.handle.net/10259/9303</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">10.1016/j.egyr.2022.12.085</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Daylighting analysis</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Daylight simulation</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Energy efficiency</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Radiance</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Visual comfort</subfield>
</datafield>
<datafield tag="245" ind1="0" ind2="0">
<subfield code="a">Exploitation of indoor illumination for typical flat dwellings in the Mediterranean area</subfield>