<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-21T19:24:34Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/10048" metadataPrefix="didl">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/10048</identifier><datestamp>2025-01-28T01:05:27Z</datestamp><setSpec>com_10259_6688</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_6689</setSpec></header><metadata><d:DIDL xmlns:d="urn:mpeg:mpeg21:2002:02-DIDL-NS" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:mpeg:mpeg21:2002:02-DIDL-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/did/didl.xsd">
<d:DIDLInfo>
<dcterms:created xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/dcterms.xsd">2025-01-27T12:31:12Z</dcterms:created>
</d:DIDLInfo>
<d:Item id="hdl_10259_10048">
<d:Descriptor>
<d:Statement mimeType="application/xml; charset=utf-8">
<dii:Identifier xmlns:dii="urn:mpeg:mpeg21:2002:01-DII-NS" xsi:schemaLocation="urn:mpeg:mpeg21:2002:01-DII-NS http://standards.iso.org/ittf/PubliclyAvailableStandards/MPEG-21_schema_files/dii/dii.xsd">urn:hdl:10259/10048</dii:Identifier>
</d:Statement>
</d:Descriptor>
<d:Descriptor>
<d:Statement mimeType="application/xml; charset=utf-8">
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title>Observational study of newborn infant parasympathetic evaluation as a comfort system in awake patients admitted to a pediatric intensive care unit</dc:title>
<dc:creator>Valencia Ramos, Juan</dc:creator>
<dc:creator>Arnaez, Juan</dc:creator>
<dc:creator>Calvo Meruelo, Sara</dc:creator>
<dc:creator>Gomez, Fernando</dc:creator>
<dc:creator>Blanco Gómez, Isabel del</dc:creator>
<dc:subject>Comfort</dc:subject>
<dc:subject>Newborn infant parasympathetic evaluation</dc:subject>
<dc:subject>COMFORT Behavior Scale</dc:subject>
<dc:subject>Nebulization</dc:subject>
<dc:subject>Bronchiolitis</dc:subject>
<dc:description>To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In order to compare NIPE and CBS values during the whole T1 to T3 period, the variable Dif-CBS was defined as the difference between maximal and minimal CBS scores, and Dif-NIPE as the difference between 75th and 25th percentile NIPE values. Analyses were carried out, firstly for the total of nebulizations and secondly comparing two different nebulization systems: a jet nebulizer (JN) and a nebulizer integrated in high flow nasal cannulas (NHF). 84 nebulizations were recorded on 14 patients with a median [25th–75th percentile] age of 6 months (3.1–9.5). A Dif-CBS of 4 points (2–7), as well as changes in CBS scores between T1 and T2, defined the nebulization as a discomfort stimulus. The NIPE system, represented as the Dif-NIPE, showed a median variation of 9 points (7–10), and was poorly correlated to Dif-CBS [rs 0.162 (P = 0.142)]. Discomfort during nebulization, assessed by CBS was greater with the JN system compared to NHF: 17 (13–22) vs 13 (9–15) (P = 0.001). NIPE monitoring detected no significant differences between both nebulization systems (P = 0.706). NIPE monitoring showed a variation in comfort during nebulization in the patient with bronchiolitis, though correlation with CBS was poor. Further research is required before NIPE can be suggested as a comfort monitoring system for the awake infant.</dc:description>
<dc:date>2025-01-27T12:31:12Z</dc:date>
<dc:date>2025-01-27T12:31:12Z</dc:date>
<dc:date>2019-02</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>1387-1307</dc:identifier>
<dc:identifier>http://hdl.handle.net/10259/10048</dc:identifier>
<dc:identifier>10.1007/s10877-019-00268-1</dc:identifier>
<dc:identifier>1573-2614</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>Journal of Clinical Monitoring and Computing. 2019, V. 33, n. 5, p. 749–755</dc:relation>
<dc:relation>https://doi.org/10.1007/s10877-019-00268-1</dc:relation>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:publisher>Springer</dc:publisher>
</oai_dc:dc>
</d:Statement>
</d:Descriptor>
<d:Component id="10259_10048_3">
<d:Resource ref="https://riubu.ubu.es/bitstream/10259/10048/3/Valencia-jcmc_2019.pdf" mimeType="application/pdf"/>
</d:Component>
</d:Item>
</d:DIDL></metadata></record></GetRecord></OAI-PMH>