<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-08-28T05:03:40Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/11977" metadataPrefix="dim">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/11977</identifier><datestamp>2026-08-28T00:06:33Z</datestamp><setSpec>com_10259_2699</setSpec><setSpec>col_10259_2707</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
<dim:field mdschema="dc" element="contributor" qualifier="advisor" authority="ace3ff54-50a5-4ea2-976b-1ad8c83c3f4c" confidence="600" orcid_id="">Romero Barriuso, Álvaro</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="advisor" authority="481" confidence="600" orcid_id="0000-0002-3607-2167">Rodríguez Sáiz, Ángel</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="261077f3-af64-4460-86d6-8aed8a919827" confidence="600" orcid_id="">Ballesteros Álvarez, Jesús Manuel</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="other" authority="cd4d7d9d-f551-494b-8050-1a6d2cb4edcb" confidence="500" orcid_id="">Universidad de Burgos. Departamento de Construcciones Arquitectónicas e Ingeniería de la Construcción y del Terreno</dim:field>
<dim:field mdschema="dc" element="date" qualifier="accessioned">2026-08-27T10:39:34Z</dim:field>
<dim:field mdschema="dc" element="date" qualifier="available">2026-08-27T10:39:34Z</dim:field>
<dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
<dim:field mdschema="dc" element="date" qualifier="submitted">2026-06-23</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10259/11977</dim:field>
<dim:field mdschema="dc" element="description" qualifier="abstract" lang="es">Este trabajo de investigación surge como respuesta a la necesidad de&#xd;
disponer de valores de referencia para la ventilación, entre marzo de 2020 y&#xd;
febrero de 2022, periodo en el que produce la reincorporación al trabajo en plena&#xd;
crisis sanitaria por COVID-19. Si bien en el año 2020 se publica el método Steady&#xd;
State CO2, que posteriormente fue adaptado por el Centro Superior de&#xd;
Investigaciones Científicas, únicamente se contempla doblar los valores de&#xd;
ventilación requeridos en la Directriz ASHRAE 62.1. Estas referencias en ningún&#xd;
caso se vinculan a la infectividad del SARS-CoV-2, el cual desarrolló múltiples&#xd;
variantes con diferentes Tasas de Infectividad, por lo que la presente Tesis&#xd;
Doctoral establece el objetivo de desarrollar una herramienta que permita&#xd;
controlar la transmisión de enfermedades a través del aire mediante&#xd;
restricciones en la ocupación de los recintos, en aras de poder adaptarla tanto a&#xd;
la infectividad del patógeno como actividad física que se esté desarrollando en&#xd;
su interior, considerando situaciones de ventilación controlada y ventilación&#xd;
natural, en ambientes tanto interiores como exteriores. El método se basa en&#xd;
determinar los caudales de ventilación que, por comparación con el aire limpio&#xd;
disponible, permiten determinar la ocupación máxima de un recinto en función&#xd;
de la actividad desarrollada. Para ambientes interiores, los resultados se&#xd;
comparan con las condiciones de ventilación en los centros municipales del&#xd;
Ayuntamiento de Móstoles, considerando la exposición de los trabajadores al&#xd;
SARS-CoV-2. Para los ambientes exteriores, se analizan los valores de CO2&#xd;
estimados y medidos durante las fiestas patronales de Móstoles de septiembre&#xd;
del 2022.</dim:field>
<dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">This research project arises in response to the need for reference values for ventilation between March 2020 and February 2022, a period during which people were returning to work in the midst of the COVID-19 health crisis. It is based on the development of a tool to control the transmission of airborne diseases through restrictions on the occupancy of premises. With a view to adapting it both to the infectivity of the pathogen and to the physical activity taking place within them, taking into account situations involving controlled ventilation and natural ventilation, in both indoor and outdoor environments.&#xd;
Indoor environments have been studied using the municipal centres of the Móstoles Town Council, taking into account workers’ exposure to SARS-CoV-2. For outdoor environments, the estimated and measured CO₂ levels during the Móstoles Patron Saint Festivities in September 2022 were analysed.</dim:field>
<dim:field mdschema="dc" element="description" qualifier="degree" lang="es">Doctorado en Ingeniería y Tecnologías Industrial, Informática y Civil</dim:field>
<dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
<dim:field mdschema="dc" element="language" qualifier="iso" lang="es">spa</dim:field>
<dim:field mdschema="dc" element="rights" lang="*">Attribution-NonCommercial-NoDerivatives 4.0 Internacional</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="uri" lang="*">http://creativecommons.org/licenses/by-nc-nd/4.0/</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="holder" lang="es">Este documento está sujeto a una licencia de uso Creative Commons, por la cual está permitido hacer copia, distribuir y comunicar públicamente la obra siempre que se cite al autor original y no se haga de él uso comercial ni obra derivada</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="accessRights" lang="es">info:eu-repo/semantics/openAccess</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Concentración de CO2</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Calidad del aire</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Ventilación natural</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Ventilación cenital</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Ventilación cruzada</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Prevención de la propagación del coronavirus</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Control de las enfermedades transmitidas por el aire</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Evaluación de la ocupación.</dim:field>
<dim:field mdschema="dc" element="subject" lang="en">CO2 concentration</dim:field>
<dim:field mdschema="dc" element="subject" lang="en">Natural ventilation</dim:field>
<dim:field mdschema="dc" element="subject" lang="en">Indoor air quality</dim:field>
<dim:field mdschema="dc" element="subject" lang="en">Airborne disease prevention</dim:field>
<dim:field mdschema="dc" element="subject" lang="en">Occupancy assessment</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="other" lang="es">Aire-Calidad</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="other" lang="es">Ventilación natural</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="other" lang="en">Air quality</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="other" lang="en">Natural ventilation</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="unesco">3108.04 Control Ambiental de Enfermedades</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="unesco">3308.01 Control de la Contaminación Atmosférica</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="unesco">2420.08 Virus Respiratorios</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="unesco">3212 Salud Publica</dim:field>
<dim:field mdschema="dc" element="title" lang="es">Propuesta de un modelo adaptativo para la gestión del riesgo de transmisión aérea de patógenos en espacios de pública concurrencia, basado en el tipo de ventilación, la calidad del aire y la tasa de infectividad</dim:field>
<dim:field mdschema="dc" element="type" lang="es">info:eu-repo/semantics/doctoralThesis</dim:field>
<dim:field mdschema="dc" element="type" qualifier="hasVersion" lang="es">info:eu-repo/semantics/acceptedVersion</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>