<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-08-28T05:03:47Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/11977" metadataPrefix="marc">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/11977</identifier><datestamp>2026-08-28T00:06:33Z</datestamp><setSpec>com_10259_2699</setSpec><setSpec>col_10259_2707</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield tag="042" ind1=" " ind2=" ">
<subfield code="a">dc</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Ballesteros Álvarez, Jesús Manuel</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2026</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Este trabajo de investigación surge como respuesta a la necesidad de&#xd;
disponer de valores de referencia para la ventilación, entre marzo de 2020 y&#xd;
febrero de 2022, periodo en el que produce la reincorporación al trabajo en plena&#xd;
crisis sanitaria por COVID-19. Si bien en el año 2020 se publica el método Steady&#xd;
State CO2, que posteriormente fue adaptado por el Centro Superior de&#xd;
Investigaciones Científicas, únicamente se contempla doblar los valores de&#xd;
ventilación requeridos en la Directriz ASHRAE 62.1. Estas referencias en ningún&#xd;
caso se vinculan a la infectividad del SARS-CoV-2, el cual desarrolló múltiples&#xd;
variantes con diferentes Tasas de Infectividad, por lo que la presente Tesis&#xd;
Doctoral establece el objetivo de desarrollar una herramienta que permita&#xd;
controlar la transmisión de enfermedades a través del aire mediante&#xd;
restricciones en la ocupación de los recintos, en aras de poder adaptarla tanto a&#xd;
la infectividad del patógeno como actividad física que se esté desarrollando en&#xd;
su interior, considerando situaciones de ventilación controlada y ventilación&#xd;
natural, en ambientes tanto interiores como exteriores. El método se basa en&#xd;
determinar los caudales de ventilación que, por comparación con el aire limpio&#xd;
disponible, permiten determinar la ocupación máxima de un recinto en función&#xd;
de la actividad desarrollada. Para ambientes interiores, los resultados se&#xd;
comparan con las condiciones de ventilación en los centros municipales del&#xd;
Ayuntamiento de Móstoles, considerando la exposición de los trabajadores al&#xd;
SARS-CoV-2. Para los ambientes exteriores, se analizan los valores de CO2&#xd;
estimados y medidos durante las fiestas patronales de Móstoles de septiembre&#xd;
del 2022.</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">This research project arises in response to the need for reference values for ventilation between March 2020 and February 2022, a period during which people were returning to work in the midst of the COVID-19 health crisis. It is based on the development of a tool to control the transmission of airborne diseases through restrictions on the occupancy of premises. With a view to adapting it both to the infectivity of the pathogen and to the physical activity taking place within them, taking into account situations involving controlled ventilation and natural ventilation, in both indoor and outdoor environments.&#xd;
Indoor environments have been studied using the municipal centres of the Móstoles Town Council, taking into account workers’ exposure to SARS-CoV-2. For outdoor environments, the estimated and measured CO₂ levels during the Móstoles Patron Saint Festivities in September 2022 were analysed.</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">https://hdl.handle.net/10259/11977</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Concentración de CO2</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Calidad del aire</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Ventilación natural</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Ventilación cenital</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Ventilación cruzada</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Prevención de la propagación del coronavirus</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Control de las enfermedades transmitidas por el aire</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Evaluación de la ocupación.</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">CO2 concentration</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Natural ventilation</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Indoor air quality</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Airborne disease prevention</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Occupancy assessment</subfield>
</datafield>
<datafield tag="245" ind1="0" ind2="0">
<subfield code="a">Propuesta de un modelo adaptativo para la gestión del riesgo de transmisión aérea de patógenos en espacios de pública concurrencia, basado en el tipo de ventilación, la calidad del aire y la tasa de infectividad</subfield>
</datafield>
</record></metadata></record></GetRecord></OAI-PMH>