<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-23T02:05:40Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/4251" metadataPrefix="mods">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/4251</identifier><datestamp>2021-11-10T09:38:26Z</datestamp><setSpec>com_10259_4249</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_4250</setSpec></header><metadata><mods:mods xmlns:mods="http://www.loc.gov/mods/v3" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:namePart>Rubio Martínez, Laura</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Sanllorente Méndez, Silvia</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Sarabia Peinador, Luis Antonio</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Ortiz Fernández, Mª Cruz</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2016-10-13T07:52:14Z</mods:dateAvailable>
</mods:extension>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2016-10-13T07:52:14Z</mods:dateAccessioned>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2014-04</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="issn">0169-7439</mods:identifier>
<mods:identifier type="uri">http://hdl.handle.net/10259/4251</mods:identifier>
<mods:identifier type="doi">10.1016/j.chemolab.2014.01.013</mods:identifier>
<mods:abstract>In this work, a headspace solid-phase microextraction and gas chromatography coupledwith mass spectrometry&#xd;
(HS-SPME-GC/MS) method for trace determination of primary aromatic amines was developed. The following&#xd;
analytes were investigated: aniline (A), 4,4′-diaminodiphenylmethane (4,4′-MDA) and 2,4-diaminotoluene&#xd;
(2,4-TDA) using 3-chloro-4-fluoroaniline (3C4FA) and 2-aminobiphenyl (2ABP) as internal standards. Prior to&#xd;
extraction the analytes were derivatized in the aqueous solution by diazotation and subsequent iodination.&#xd;
The derivativeswere extracted byHS-SPME using a PDMS/DVB fiber and analyzed by GC/MS. A D-optimal design&#xd;
was used to study the parameters affecting the HS-SPME procedure and the derivatization step. Two experimental&#xd;
factors at two levels and one factor at three levels were considered: (i) reaction time, (ii) extraction temperature,&#xd;
and (iii) extraction time in the headspace. The interaction between the extraction temperature and&#xd;
extraction time was considered in the proposed model. The loadings in the sample mode estimated by a&#xd;
PARAFAC (parallel factor analysis) decomposition for each analyte were the response used in the design because&#xd;
they are proportional to the amount of analyte extracted. The optimum conditions for the best extraction of the&#xd;
analytes were achieved when the reaction time was 20 min, the extraction temperature was 50 °C and the&#xd;
extraction time was 25 min. The interaction was significant.&#xd;
A calibration based on a PARAFAC decomposition provided the following values of decision limit (CCα): 1.07 μgL−1&#xd;
for A, 1.23 μg L−1 for 2,4-TDA and 0.83 μg L−1 for 4,4′-MDA for a probability of false positive fixed at 5%. Also, the&#xd;
accuracy (trueness and precision) of the procedurewas assessed. Furthermore, all the analyteswere unequivocally&#xd;
identified.&#xd;
Finally, the method was applied to spiked water samples and polyamide cooking utensils (spoons). 3% (w/v)&#xd;
acetic acid in aqueous solution was used as food simulant for testing migration from polyamide kitchenware.&#xd;
Detectable levels of 4,4′-diaminodiphenylmethane and aniline were found in food simulant from some of the&#xd;
investigated cooking utensils.</mods:abstract>
<mods:language>
<mods:languageTerm>eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">http://creativecommons.org/licenses/by-nc-nd/4.0/</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">info:eu-repo/semantics/openAccess</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">Attribution-NonCommercial-NoDerivatives 4.0 International</mods:accessCondition>
<mods:subject>
<mods:topic>Primary aromatic amines</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>HS-SPME-GC/MS</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Derivatization</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>D-optimal design</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>PARAFAC</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Migration test</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>Optimization of a headspace solid-phase microextraction and gas chromatography/mass spectrometry procedure for the determination of aromatic amines in water and in polyamide spoons</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/article</mods:genre>
</mods:mods></metadata></record></GetRecord></OAI-PMH>