<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-17T11:21:23Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/4380" metadataPrefix="etdms">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/4380</identifier><datestamp>2022-04-29T12:02:47Z</datestamp><setSpec>com_10259_4376</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_4377</setSpec></header><metadata><thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.0/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.0/ http://www.ndltd.org/standards/metadata/etdms/1.0/etdms.xsd">
<title>Acetylcholinesterase Inhibition-Based Biosensor for Aluminum(III) Chronoamperometric Determination in Aqueous Media</title>
<title>Artículo</title>
<creator>Barquero Quirós, Miriam</creator>
<creator>Domínguez Renedo, Olga</creator>
<creator>Alonso Lomillo, Mª Asunción</creator>
<creator>Arcos Martínez, Julia</creator>
<subject>acetylcholinesterase</subject>
<subject>biosensor</subject>
<subject>aluminum</subject>
<subject>acetylthiocholine iodide</subject>
<subject>screen-printed electrodes</subject>
<subject>gold nanoparticles</subject>
<description>A novel amperometric biosensor for the determination of Al(III) based on the inhibition of the enzyme acetylcholinesterase has been developed. The immobilization of the enzyme was performed on screen-printed carbon electrodes modified with gold nanoparticles. The oxidation signal of acetylthiocholine iodide enzyme substrate was affected by the presence of Al(III) ions leading to a decrease in the amperometric current. The developed system has a detection limit of 2.1 ± 0.1 μM for Al(III). The reproducibility of the method is 8.1% (n = 4). Main interferences include Mo(VI), W(VI) and Hg(II) ions. The developed method was successfully applied to the determination of Al(III) in spiked tap water . The analysis of a certified standard reference material was also carried out. Both results agree with the certified values considering the respective associated uncertainties.</description>
<date>2017-03-20</date>
<date>2017-03-20</date>
<date>2014-05</date>
<type>info:eu-repo/semantics/article</type>
<identifier>http://hdl.handle.net/10259/4380</identifier>
<language>eng</language>
<relation>Sensors, 2014, V. 14, n. 5, p. 8203-8216</relation>
<relation>http://dx.doi.org/10.3390/s140508203</relation>