<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-30T08:47:38Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/4696" metadataPrefix="etdms">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/4696</identifier><datestamp>2024-05-14T11:26:49Z</datestamp><setSpec>com_10259_4393</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_4394</setSpec></header><metadata><thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.0/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.0/ http://www.ndltd.org/standards/metadata/etdms/1.0/etdms.xsd">
<title>Performance of grid-tied PV facilities based on real data in Spain: Central inverter versus string system</title>
<creator>Diez Mediavilla, Montserrat</creator>
<creator>Dieste Velasco, Mª Isabel</creator>
<creator>Rodríguez Amigo, María del Carmen</creator>
<creator>García Calderón, Teófilo</creator>
<creator>Alonso Tristán, Cristina</creator>
<subject>Inverter layout</subject>
<subject>PV system</subject>
<subject>Performance</subject>
<subject>Grid-connected system</subject>
<description>Two complete years of operation of two grid-tied PV facilities is presented. Energetic and economic performance of both installations has been compared. Located in the same place, the installation of these facilities followed the same construction criteria – PV panels, panel support system and wiring – and the facilities are exposed to the same atmospheric temperature and solar radiation. They differ with regard to their inverter topology used: one facility uses a central inverter and the other a string inverter configuration. The performance of the facilities has been determined using a procedure based on a small number of easily obtained parameters and the knowledge of the analyzed system and its operation mode. Electrical losses have been calculated for both systems and a complete comparison between them has been carried out. The results have shown better performance for distributed system in economic and energetic terms.</description>
<date>2018-01-11</date>
<date>2018-01-11</date>
<date>2014-10</date>
<type>info:eu-repo/semantics/article</type>
<identifier>0196-8904</identifier>
<identifier>http://hdl.handle.net/10259/4696</identifier>
<identifier>10.1016/j.enconman.2014.06.087</identifier>
<language>eng</language>
<relation>Energy Conversion and Management. 2014,  V. 86, p. 1128-1133</relation>
<relation>https://doi.org/10.1016/j.enconman.2014.06.087</relation>
<relation>info:eu-repo/grantAgreement/MINECO/ENE2011-27511</relation>
<relation>info:eu-repo/grantAgreement/JCyL/BU358A12-2</relation>
<rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</rights>
<rights>info:eu-repo/semantics/openAccess</rights>
<rights>Attribution-NonCommercial-NoDerivatives 4.0 International</rights>
<publisher>Elsevier</publisher>
</thesis></metadata></record></GetRecord></OAI-PMH>