<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-07-29T05:59:57Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/5332" metadataPrefix="marc">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/5332</identifier><datestamp>2022-04-07T11:32:51Z</datestamp><setSpec>com_10259_4376</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_4377</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield tag="042" ind1=" " ind2=" ">
<subfield code="a">dc</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Domínguez Renedo, Olga</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Navarro Cuñado, A. Marta</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Ventas Romay, Eduardo</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Alonso Lomillo, Mª Asunción</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2019-05</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Three different methods for the determination of Al(III) in aqueous samples were compared. The different described procedures were based on the formation of the Al(III)-morin complex. UV–Vis spectrophotometry, spectrofluorimetry and differential pulse adsorptive stripping voltammetry (DPAdSV) techniques were compared under optimized experimental conditions. The DPAdSV method showed a better performance for the analysis of Al(III) in terms of capability of detection (70 nM) in comparison with the value obtained for UV–Vis spectrophotometric (300 nM) and spectrofluorimetic (110 nM) techniques. Thus, DPAdSV method was selected for the analysis of aluminium in river, tap and bottled water samples under the following optimized experimental conditions: pH = 4.4, deposition potential = +243 mV, deposition time = 210 s, giving satisfactory results.</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">0039-9140</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">http://hdl.handle.net/10259/5332</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">10.1016/j.talanta.2018.12.048</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Aluminium</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Morin</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Stripping voltammetry</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">UV–Vis spectroscopy</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Fluorescence</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Water samples</subfield>
</datafield>
<datafield tag="245" ind1="0" ind2="0">
<subfield code="a">Determination of aluminium using different techniques based on the Al(III)-morin complex</subfield>
</datafield>