<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-20T00:09:17Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/5631" metadataPrefix="mods">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/5631</identifier><datestamp>2022-11-21T12:01:24Z</datestamp><setSpec>com_10259_4249</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_4250</setSpec></header><metadata><mods:mods xmlns:mods="http://www.loc.gov/mods/v3" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:namePart>Arce Antón, Mar</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Ruiz Miguel, Santiago</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Sanllorente Méndez, Silvia</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Ortiz Fernández, Mª Cruz</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Sarabia Peinador, Luis Antonio</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Sánchez Pastor, Mª Sagrario</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2021-03-01T13:02:34Z</mods:dateAvailable>
</mods:extension>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2021-03-01T13:02:34Z</mods:dateAccessioned>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2021</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="issn">0003-2670</mods:identifier>
<mods:identifier type="uri">http://hdl.handle.net/10259/5631</mods:identifier>
<mods:identifier type="doi">10.1016/j.aca.2021.338217</mods:identifier>
<mods:abstract>The paper shows a procedure for selecting the control method parameters (factors) to obtain a preset ‘analytical target profile’ when a liquid chromatographic technique is going to be carried out for the simultaneous determination of five bisphenols (bisphenol-A, bisphenol-S, bisphenol-F, bisphenol-Z and bisphenol-AF), some of them regulated by the European Union.&#xd;
&#xd;
The procedure has three steps. The first consists of building a D-optimal combined design (mixture-process design) for the control method parameters, which are the composition of the ternary mobile phase and its flow rate. The second step is to fit a PLS2 model to predict six analytical responses (namely, the resolution between each pair of consecutive peaks, and the initial and final chromatographic time) as a function of the control method parameters. The third final step is the inversion of the PLS2 model to obtain the conditions needed for attaining a preset analytical target profile.&#xd;
&#xd;
The computational inversion of the PLS2 prediction model looking for the Pareto front of these six responses provides a set of experimental conditions to conduct the chromatographic determination, specifically 22% of water, mixed with 58% methanol and 20% of acetonitrile, keeping the flow rate at 0.66 mL min−1. These conditions give a chromatogram with retention times of 2.180, 2.452, 2.764, 3.249 and 3.775 min for BPS, BPF, BPA, BPAF and BPZ, respectively, and excellent resolution among all the chromatographic peaks.&#xd;
&#xd;
Finally, the analytical method is validated under the selected experimental conditions, in terms of trueness and precision. In addition, the detection capability for the five bisphenols were: 596, 334, 424, 458 and 1156 μg L−1, with probabilities of false positive and of false negative equal to 0.05.</mods:abstract>
<mods:language>
<mods:languageTerm>eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">http://creativecommons.org/licenses/by-nc-nd/4.0/</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">info:eu-repo/semantics/openAccess</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">Attribution-NonCommercial-NoDerivatives 4.0 Internacional</mods:accessCondition>
<mods:subject>
<mods:topic>Process analytical technology</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Partial least squares</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Pareto optimality</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Bisphenol AHPLC-DAD</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Computational latent variable model inversion</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>A new approach based on inversion of a partial least squares model searching for a preset analytical target profile. Application to the determination of five bisphenols by liquid chromatography with diode array detector</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/article</mods:genre>
</mods:mods></metadata></record></GetRecord></OAI-PMH>