<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-23T11:24:59Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/7832" metadataPrefix="marc">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/7832</identifier><datestamp>2024-05-10T09:47:25Z</datestamp><setSpec>com_10259_2699</setSpec><setSpec>col_10259_2707</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield tag="042" ind1=" " ind2=" ">
<subfield code="a">dc</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Sancho Calderón, Diego</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2022</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">La congelación artificial del terreno es un método utilizado en ingeniería civil y minera. Al&#xd;
congelar el terreno, su resistencia aumenta y se impermeabiliza. Cálculos térmicos con cambio&#xd;
de fase son necesarios para diseñar estos trabajos. Estos cálculos se pueden realizar con&#xd;
modelos numéricos o soluciones analíticas. En esta tesis se han investigado los parámetros que&#xd;
influyen en la precisión de los métodos numéricos mediante un análisis de sensibilidad y se han&#xd;
condensado los resultados en un código de buenas prácticas. Además, se ha utilizado un modelo&#xd;
numérico verificado para investigar la precisión de las soluciones analíticas. Se ha concluido que&#xd;
la solución más precisa para el problema de una tubería de congelación es la de Ständer.&#xd;
También se ha ajustado la solución analítica de Sanger &amp; Sayles para una tubería de congelación,&#xd;
que presenta una mejora de precisión significativa. Finalmente, se han utilizado datos&#xd;
experimentales para confirmar las conclusiones.</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Artificial ground freezing is a method used in civil and mining engineering for ground&#xd;
stabilisation and groundwater cut-off. In order to design these works, thermal calculations with&#xd;
phase change are required, which can be performed by numerical models or analytical solutions.&#xd;
In this thesis, the parameters which influence the accuracy of numerical methods were&#xd;
investigated by means of a sensitivity analysis and the results were condensed in a code of good&#xd;
practice. A verified numerical model was used to investigate the accuracy of analytical solutions.&#xd;
It was concluded that the most accurate solution for the single freeze pipe problem is Ständer’s.&#xd;
Additionally, Sanger &amp; Sayles’ solution for the single freeze pipe has been adjusted, obtaining a&#xd;
significant accuracy improvement. Finally, experimental data were used to confirm the&#xd;
conclusions.</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">http://hdl.handle.net/10259/7832</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">10.36443/10259/7832</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Congelación artificial de terreno</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Diseño térmico</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Problema de Stefan</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Solución analítica</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Modelación numérica</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Artificial ground freezing</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Thermal design</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Stefan problem</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Analytical solution</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Numerical modelling</subfield>
</datafield>
<datafield tag="245" ind1="0" ind2="0">
<subfield code="a">Improved engineering solutions for thermal design of artificial ground freezing</subfield>
</datafield>