<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-02T03:39:40Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/8578" metadataPrefix="mets">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/8578</identifier><datestamp>2024-02-06T01:05:23Z</datestamp><setSpec>com_10259_3847</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_7109</setSpec><setSpec>col_10259_7409</setSpec></header><metadata><mets xmlns="http://www.loc.gov/METS/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd" PROFILE="DSpace METS SIP Profile 1.0" TYPE="DSpace ITEM" ID="&#xa;&#x9;&#x9;&#x9;&#x9;DSpace_ITEM_10259-8578" OBJID="&#xa;&#x9;&#x9;&#x9;&#x9;hdl:10259/8578">
<metsHdr CREATEDATE="2026-06-02T05:39:40Z">
<agent TYPE="ORGANIZATION" ROLE="CUSTODIAN">
<name>Repositorio Institucional de la Universidad de Burgos</name>
</agent>
</metsHdr>
<dmdSec ID="DMD_10259_8578">
<mdWrap MDTYPE="MODS">
<xmlData xmlns:mods="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:mods xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Sedano, Javier</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Villar, José Ramón</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Curiel Herrera, Leticia Elena</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Cal, Enrique de la</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Corchado, Emilio</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2024-02-05T11:13:07Z</mods:dateAccessioned>
</mods:extension>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2024-02-05T11:13:07Z</mods:dateAvailable>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2010</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="issn">0302-9743</mods:identifier>
<mods:identifier type="uri">http://hdl.handle.net/10259/8578</mods:identifier>
<mods:identifier type="doi">10.1007/978-3-642-13033-5_65</mods:identifier>
<mods:identifier type="essn">1611-3349</mods:identifier>
<mods:abstract>Improving the detection of thermal insulation failures in buildings includes the development of models for heating process and fabric gain -heat flux&#xd;
through exterior walls in the building-. Thermal insulation standards are now&#xd;
contractual obligations in new buildings, the energy efficiency in the case of&#xd;
buildings constructed before the regulations adopted is still an open issue, and&#xd;
the assumption is that it will be based on heat flux and conductivity measurement. A three-step procedure is proposed in this study that begins by considering the local building and heating system regulations as well as the specific features of the climate zone. Firstly, the dynamic thermal performance of different&#xd;
variables is specifically modeled. Secondly, an exploratory projection pursuit&#xd;
method called Cooperative Maximum-Likelihood Hebbian Learning is used to&#xd;
extract the relevant features. Finally, a supervised neural model and identification techniques are applied, in order to detect the heat flux through exterior&#xd;
walls in the building. The reliability of the proposed method is validated for a&#xd;
winter zone, associated to several cities in Spain.</mods:abstract>
<mods:language>
<mods:languageTerm authority="rfc3066">eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction"/>
<mods:subject>
<mods:topic>Computational Intelligence</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Soft computing Systems</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Identification Systems</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Artificial Neural Networks</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Non-linear Systems</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>Modelling of Heat Flux in Building Using Soft-Computing Techniques</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/bookPart</mods:genre>
</mods:mods>
</xmlData>
</mdWrap>
</dmdSec>
<amdSec ID="TMD_10259_8578">
<rightsMD ID="RIG_10259_8578">
<mdWrap OTHERMDTYPE="DSpaceDepositLicense" MDTYPE="OTHER" MIMETYPE="text/plain">
<binData>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</binData>
</mdWrap>
</rightsMD>
</amdSec>
<amdSec ID="FO_10259_8578_1">
<techMD ID="TECH_O_10259_8578_1">
<mdWrap MDTYPE="PREMIS">
<xmlData xmlns:premis="http://www.loc.gov/standards/premis" xsi:schemaLocation="http://www.loc.gov/standards/premis http://www.loc.gov/standards/premis/PREMIS-v1-0.xsd">
<premis:premis>
<premis:object>
<premis:objectIdentifier>
<premis:objectIdentifierType>URL</premis:objectIdentifierType>
<premis:objectIdentifierValue>https://riubu.ubu.es/bitstream/10259/8578/1/Sedano-Modelling_heat_flux_building_2010.pdf</premis:objectIdentifierValue>
</premis:objectIdentifier>
<premis:objectCategory>File</premis:objectCategory>
<premis:objectCharacteristics>
<premis:fixity>
<premis:messageDigestAlgorithm>MD5</premis:messageDigestAlgorithm>
<premis:messageDigest>ed47c105e523725227af93156ddb1694</premis:messageDigest>
</premis:fixity>
<premis:size>485426</premis:size>
<premis:format>
<premis:formatDesignation>
<premis:formatName>application/pdf</premis:formatName>
</premis:formatDesignation>
</premis:format>
</premis:objectCharacteristics>
<premis:originalName>Sedano-Modelling_heat_flux_building_2010.pdf</premis:originalName>
</premis:object>
</premis:premis>
</xmlData>
</mdWrap>
</techMD>
</amdSec>
<fileSec>
<fileGrp USE="ORIGINAL">
<file ID="BITSTREAM_ORIGINAL_10259_8578_1" MIMETYPE="application/pdf" SEQ="1" SIZE="485426" CHECKSUM="ed47c105e523725227af93156ddb1694" CHECKSUMTYPE="MD5" ADMID="FO_10259_8578_1" GROUPID="GROUP_BITSTREAM_10259_8578_1">
<FLocat xlink:type="simple" LOCTYPE="URL" xlink:href="https://riubu.ubu.es/bitstream/10259/8578/1/Sedano-Modelling_heat_flux_building_2010.pdf"/>
</file>
</fileGrp>
</fileSec>
<structMap TYPE="LOGICAL" LABEL="DSpace Object">
<div TYPE="DSpace Object Contents" ADMID="DMD_10259_8578">
<div TYPE="DSpace BITSTREAM">
<fptr FILEID="BITSTREAM_ORIGINAL_10259_8578_1"/>
</div>
</div>
</structMap>
</mets></metadata></record></GetRecord></OAI-PMH>