<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-21T14:32:34Z</responseDate><request verb="GetRecord" identifier="oai:riubu.ubu.es:10259/8947" metadataPrefix="mods">https://riubu.ubu.es/oai/request</request><GetRecord><record><header><identifier>oai:riubu.ubu.es:10259/8947</identifier><datestamp>2024-05-14T11:42:29Z</datestamp><setSpec>com_10259_4707</setSpec><setSpec>com_10259_5086</setSpec><setSpec>com_10259_2604</setSpec><setSpec>col_10259_8861</setSpec></header><metadata><mods:mods xmlns:mods="http://www.loc.gov/mods/v3" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:namePart>Briones Llorente, Raúl</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Montero García, Eduardo</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2024-04-16T08:07:33Z</mods:dateAvailable>
</mods:extension>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2024-04-16T08:07:33Z</mods:dateAccessioned>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2017-07</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="uri">http://hdl.handle.net/10259/8947</mods:identifier>
<mods:abstract>Achieving a reasonable level of airtightness is important for the energy efficiency of living spaces and the&#xd;
comfort of occupants. The benefits of improved insulation levels and more energy efficient heating systems&#xd;
are lost if warm air can leak out of a building and cold air can leak in. Poor airtightness can be responsible&#xd;
for up to 40% of heat loss from buildings. Airtight buildings require airtight windows. Airtightness of windows&#xd;
is often evaluated in lab conditions in the context of initial type testing. Testing methods can be found in&#xd;
several international standards, leading to airtightness classifications of windows for building codes. The&#xd;
level of airtightness achieved is measured as air permeability, as the quantity of air that leaks into or out of&#xd;
the window per hour. Airtightness of windows is typically expressed per meter opening joint or per square&#xd;
meter. Nevertheless, airtightness of window is highly sensitive with respect to wind conditions, mostly speed&#xd;
and direction. Increased attention to energy efficiency and airtightness of buildings has led to more research&#xd;
on the performance of windows, and can be estimated by appropriate simulation. This work presents a case&#xd;
study of the influence of wind speed and direction on the thermal load of a tertiary building due to leakage&#xd;
through windows. Transient simulation by means of Transient System Simulation (TRNSYS) package is&#xd;
presented. Results are analyzed as a function of standardized window type. Besides, relative influence of the&#xd;
internal layers of the façade on the thermal load of the building is studied. Three alternative cases of high&#xd;
thermal inertia are compared with the existing one with low thermal inertia.</mods:abstract>
<mods:language>
<mods:languageTerm>eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">info:eu-repo/semantics/openAccess</mods:accessCondition>
<mods:subject>
<mods:topic>Airtightness</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Energy efficiency</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Thermal Inertia</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>TRNSYS</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>Transient simulation of the influence of wind conditions on the airtightness of windows. A case study for a tertiary building</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/conferenceObject</mods:genre>
</mods:mods></metadata></record></GetRecord></OAI-PMH>