2024-03-28T22:31:52Zhttps://riubu.ubu.es/oai/requestoai:riubu.ubu.es:10259/49352021-11-10T09:38:18Zcom_10259_3844com_10259_5086com_10259_2604col_10259_3845
Repositorio Institucional de la Universidad de Burgos
author
Martin Yerga, Daniel .
author
Pérez Junquera, Alejandro .
author
González García, Maria Begoña .
author
Perales Rondon, Juan Víctor
author
Heras, Aránzazu
author
Colina, Álvaro
author
Hernández Santos, David .
author
Fanjul Bolado, Pablo .
2018-09-12T11:39:21Z
2018-02
0013-4686
http://hdl.handle.net/10259/4935
10.1016/j.electacta.2018.01.060
Surface enhanced Raman scattering (SERS) is a powerful technique based on the intensification of the Raman signal because of the interaction of a molecule with a nanostructured metal surface. Electrochemically roughened silver has been widely used as SERS substrate in the qualitative detection of analytes at the ultra-trace level. However, its potential for quantitative analysis has not been widely exploited yet. In this work, the combination of time-resolved Raman spectroelectrochemistry with silver screen-printed electrodes (SPE) is proposed as a novel methodology for the preparation of SERS substrates. The in situ activation of a SERS substrate is performed simultaneously with the analytical detection of a probe molecule, controlling the process related to the preparation of the substrate and performing the analytical measurement in real time. The results show the good performance of silver SPE as electrochemically-induced surface-enhanced Raman scattering substrates. Raman spectra were recorded at fairly low integration times (250 ms), obtaining useful spectroelectrochemical information of the processes occurring at the SPE surface with excellent time-resolution. By recording the microscopic surface images at different times during the experiment, we correlated the different data obtained: structural, optical and electrochemical. Finally, the in situ activation process was used to obtain a suitable in situ SERS signal for ferricyanide and tris(bipyridine)ruthenium (II) quantification. The detection of the analytes at concentrations of a few tens of nM was possible with a low integration time (2 s) and good precision, demonstrating the exceptional performance of the Raman spectroelectrochemical method and the possibility to use cost-effective screen-printed electrodes for applications where a high sensitivity is needed.
eng
Attribution-NonCommercial-NoDerivatives 4.0 International
Surface-enhanced Raman scattering
Screen-printed electrodes
Electrochemistry
Raman spectroelectrochemistry
Quantitative Raman spectroelectrochemistry using silver screen-printed electrodes
info:eu-repo/semantics/article
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
URL
https://riubu.ubu.es/bitstream/10259/4935/1/EA2018_Raman.pdf
File
MD5
b14c9d9c0947b5e44902bec9105125f1
3244392
application/pdf
EA2018_Raman.pdf
URL
https://riubu.ubu.es/bitstream/10259/4935/6/EA2018_Raman.pdf.txt
File
MD5
4cdb993bb8ca193c35028b607aee3cbc
49776
text/plain
EA2018_Raman.pdf.txt