2024-03-29T06:07:58Zhttps://riubu.ubu.es/oai/requestoai:riubu.ubu.es:10259/50122022-04-26T11:42:13Zcom_10259_2699col_10259_2727
Determinación electroquímica de vanadio y tungsteno en aguas con electrodos serigrafiados modificados con nanomateriales y enzimas
Alvarado Gámez, Ana Lorena
Arcos Martínez, Julia
Universidad de Burgos. Departamento de Química
fosfatasa alcalina
lacasa
nanopartículas de oro
electrodos serigrafiados de carbono SPCE
tungsteno
alkaline phosphatase
laccase
gold nanoparticles
screen printed carcon electrodes
tungsten
Se han desarrollado diferentes biosensores amperométricos basados en SPCE para determinar vanadio y tungsteno como contaminantes emergentes en aguas, mediante inhibición de la actividad enzimática de la fosfatasa alcalina sobre los sustratos 5-monofosfato de riboflavina y p-nitrofenilfosfato para vanadio, y para tungsteno la fosfatasa alcalina con 2-fosfo-L-ascorbato trisódico y la enzima lacasa sobre catecol. Se utilizaron electrodos SPCE modificados con AuNPs. con la enzima lacasa también se han modificado las superficies del electrodo con SAMs de ácido 3-mercaptopropiónico y con MWCNTs sobre las AuNPs. Se evaluó el desempeño de los biosensores desarrollados, como LOD entre 3.9 M y 0.18 M, la repetibilidad y reproducibilidad, entre 8% y 2% como RSD, además la exactitud con patrones certificados y veracidad con muestras de agua enriquecidos con patrones certificados y recuperaciones obtenidas entre 98 y 102 %.
They were developed four amperometric biosensors to determine vanadium and tungsten as emergent contaminants in water by means of alkaline phospahatse inhibition from this metals, using riboflavine-5-monophosphate and p-nitrophenyl phosphate as substrates for vanadium, and alkaline phosphatase and 2-phospho-L-ascorbic acid, and laccase catechol respectivelly for tungsten determination. They were used modified SPCEs with AuNPs and laccase enzyme, also with SAMS from 3-mercaptopropionic acid and MWCNTs. It was evaluated the performance of the developed biosensors such as LOD between 3.9 M y 0.18 M, repeatability and reproducibility between 8% and 2% as RSD, accuracy with SRM standards and trueness with enriched water samples, with recoveries between 98% and 102%.
2018-11-21T10:30:48Z
2018-11-21T10:30:48Z
2016
2016
info:eu-repo/semantics/doctoralThesis
http://hdl.handle.net/10259/5012
10.36443/10259/5012
spa
http://creativecommons.org/licenses/by-nc-nd/4.0/
Este documento está sujeto a una licencia de uso Creative Commons, por la cual está permitido hacer copia, distribuir y comunicar públicamente la obra siempre que se cite al autor original y no se haga de él uso comercial ni obra derivada
info:eu-repo/semantics/openAccess
Attribution-NonCommercial-NoDerivatives 4.0 International