RT info:eu-repo/semantics/article T1 Comparing Methods for Calculating Cross‐Sectional Properties From High‐Resolution CT Scans in Dry Bone: The Case of the Non‐Adult Femoral Midneck A1 Muñoz Guarinos, Julia A1 García González, Rebeca A1 Carretero Díaz, José Miguel A1 Rodríguez, Laura K1 Biomechanics K1 Development K1 Femoral midneck K1 Growth K1 Ontogeny K1 Anatomía Humana K1 Human anatomy K1 Restos humanos (Arqueología) K1 Human remains (Archaeology) AB Objective: This paper explores the various protocols for deriving endosteal and periosteal contours of the femoral midneckcross-section in non-adult individuals using EPmacroJ.Materials and Methods: We analyzed femoral midneck cross-sectional contours in a total sample of 55 femora belonging tomedieval individuals ranging in age between 2 and 20 years. Femoral midneck cross-sections were taken on high-resolution CTimages and analyzed by EPJMacro in FIJI. Cross-sectional properties were obtained from periosteal and endosteal contoursderived by manual, automatic, spline, and ellipse techniques. Agreement between the manual and the other techniques wasevaluated using percent prediction error (%PE) and following the Bland–Altman approach.Results: All the evaluated techniques used for deriving the periosteal and endosteal contours at the femoral midneck cross-section in non-adult individuals have proven to be interchangeable with manual processing, except for the spline technique forthe endosteal contour. The narrowest limits of agreement were obtained for the total area, moderate limits of agreement werefound for the cortical and medullary areas, and the widest limits of agreement were observed in the section moduli.Discussion: The automatic processing of the periosteal and endosteal contours shows a high level of agreement with the man-ual processing of both contours. Semi-automatic approaches (spline and ellipse) provide less agreement, especially in sectionmoduli. This suggests that inaccuracies in deriving the endosteal contour significantly affect section moduli. The best approachfor extracting the geometric properties of femoral midneck cross-sections is a combination of automatic and manual methods,although automatic methods alone are also effective. PB Wiley SN 2692-7691 YR 2025 FD 2025-03 LK http://hdl.handle.net/10259/10412 UL http://hdl.handle.net/10259/10412 LA eng NO This work was supported by the Ministerio de Ciencia, Innovación y Universidades, Grant PID2021-122355NB-C31 funded by MCIN/AEI/10.1. DS Repositorio Institucional de la Universidad de Burgos RD 19-abr-2025