Universidad de Burgos RIUBU Principal Default Universidad de Burgos RIUBU Principal Default
  • español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
Universidad de Burgos RIUBU Principal Default
  • Ayuda
  • Contact Us
  • Send Feedback
  • Acceso abierto
    • Archivar en RIUBU
    • Acuerdos editoriales para la publicación en acceso abierto
    • Controla tus derechos, facilita el acceso abierto
    • Sobre el acceso abierto y la UBU
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of RIUBUCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Compartir

    View Item 
    •   RIUBU Home
    • E-Prints
    • Untitled
    • Untitled
    • Artículos Q&C
    • View Item
    •   RIUBU Home
    • E-Prints
    • Untitled
    • Untitled
    • Artículos Q&C
    • View Item

    Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10259/5058

    Título
    Signal transfer with excitation-emission matrices between a portable fluorimeter based on light-emitting diodes and a master fluorimeter
    Autor
    Sanllorente Méndez, SilviaUBU authority Orcid
    Rubio Martínez, LauraUBU authority Orcid
    Ortiz Fernández, Mª CruzUBU authority Orcid
    Sarabia Peinador, Luis AntonioUBU authority Orcid
    Publicado en
    Sensors and Actuators B: Chemical. 2019, V. 285, p. 240-247
    Editorial
    Elsevier
    Fecha de publicación
    2019-04
    ISSN
    0925-4005
    DOI
    10.1016/j.snb.2019.01.051
    Abstract
    In this work, the transfer of the excitation-emission matrices between a portable fluorimeter based on LEDs and a master fluorimeter based on a xenon source was carried out. Enrofloxacin was the analyte of interest and it was measured alone or in binary mixtures with flumequine (partially overlapped signals) or with ciprofloxacin (fully overlapped signals). The maintenance and transfer of the unequivocal identification of the fluorophores between both instruments are shown. The precision in the determination performed with the portable fluorimeter approximated to that made with the master fluorimeter using this transfer and it did not introduce bias. The correlation coefficients of the calibrations based on PARAFAC using EEM signals were higher than 0.999, whereas the values of the capability of detection ranged from 14.8 to 26.9 μg L−1 for probabilities of false positive and false negative fixed at 0.05. These results contribute to the effort to perform the fluorimetric detection outside the laboratory and to promote the use of databases of fluorescence spectra for the unequivocal identification in remote of fluorophores of interest and/or regulated.
    Palabras clave
    Signal transfer
    Portable fluorimeter
    Excitation-emission fluorescence
    PARAFAC
    Capability of detection
    Enrofloxacin
    Materia
    Química analítica
    Chemistry, Analytic
    URI
    http://hdl.handle.net/10259/5058
    Versión del editor
    https://doi.org/10.1016/j.snb.2019.01.051
    Collections
    • Artículos Q&C
    Attribution-NonCommercial-NoDerivatives 4.0 International
    Documento(s) sujeto(s) a una licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
    Files in this item
    Nombre:
    Sanllorente-sabc_2019.pdf
    Tamaño:
    673.6Kb
    Formato: