Universidad de Burgos RIUBU Principal Default Universidad de Burgos RIUBU Principal Default
  • español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
Universidad de Burgos RIUBU Principal Default
  • Ayuda
  • Contact Us
  • Send Feedback
  • Acceso abierto
    • Archivar en RIUBU
    • Acuerdos editoriales para la publicación en acceso abierto
    • Controla tus derechos, facilita el acceso abierto
    • Sobre el acceso abierto y la UBU
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of RIUBUCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Compartir

    View Item 
    •   RIUBU Home
    • E-Prints and Research Data
    • Untitled
    • Untitled
    • Artículos GAIN
    • View Item
    •   RIUBU Home
    • E-Prints and Research Data
    • Untitled
    • Untitled
    • Artículos GAIN
    • View Item

    Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10259/3856

    Título
    Monitoring charge transfer at polarisable liquid/liquid interfaces employing time-resolved Raman spectroelectrochemistry
    Autor
    Ibáñez Martínez, DavidUBU authority Orcid
    Plana, Daniela .
    Heras Vidaurre, AránzazuUBU authority Orcid
    Fermín, David J. .
    Colina Santamaría, ÁlvaroUBU authority Orcid
    Publicado en
    Electrochemistry Communications. 2015, V. 54, p. 14–17
    Editorial
    Elsevier
    Fecha de publicación
    2015-05
    ISSN
    1388-2481
    DOI
    10.1016/j.elecom.2015.02.012
    Abstract
    In-situ Raman spectroscopy is implemented for the first time to monitor dynamic charge transfer processes at polarisable interfaces between two immiscible electrolyte solutions (ITIES) in real time. A custom-designed new electrochemical cell is described which allows probing the Raman signals of ferroin ions as a function of the potential applied across the water|1,2-dichlorobenzene (DCB) interface. This approach is also used for investigating the heterogeneous electron transfer reaction involving dimethylferrocene in DCB and potassium hexacyanoferrate (II/III) in the aqueous phase. The evolution of the Raman signals during potentiodynamic measurements is recorded in real-time with a resolution of a few seconds.
    Palabras clave
    Liquid/liquid interfaces
    Ion transfer
    Electron transfer
    In-situ Raman spectroscopy
    Materia
    Química analítica
    Chemistry, Analytic
    URI
    http://hdl.handle.net/10259/3856
    Versión del editor
    http://dx.doi.org/10.1016/j.elecom.2015.02.012
    Collections
    • Artículos GAIN
    Files in this item
    Nombre:
    Ibáñez-EC_2015.pdf
    Tamaño:
    442.6Kb
    Formato:
    Adobe PDF
    Thumbnail
    FilesOpen

    Métricas