Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10259/5371
Título
Determination of Volatiles in Mouse Urine by Headspace Solid Phase Microextraction and Gas Chromatography-Mass Spectrometry
Publicado en
Analytical Letters. 2014, V. 47, n. 5, p. 721-729
Editorial
Taylor & Francis Group
Fecha de publicación
2014-03
ISSN
0003-2719
DOI
10.1080/00032719.2013.853182
Resumen
The extraction and determination of volatile compounds in mice urine were performed using headspace solid-phase microextraction and gas chromatography-mass spectrometry. In order to optimize the extraction conditions, experimental design was applied. A sample volume of 108 µl, a temperature of 148.6°C, and a time of 94 minutes were found to be the optimal conditions. Samples of male and female mouse urine were analyzed to determine volatile compound profiles. A total of 36 organic compounds including ketones, aldehydes, and terpenes were detected. The results revealed that compounds such as 2-isopropyl-4,5-dihydrothiazole, which is considered a male sexual pheromone, were only detected in male urine samples, whereas others like benzaldehyde were especially abundant in female mouse urine. A comparison of female samples corresponding to different stages of the estrous cycle was also performed.
Palabras clave
Experimental design
Gas chromatography-mass spectrometry (GC-MS)
Headspace-solid-phase micro-extraction (HS-SPME)
Mouse urine
Volatile organic compounds
Materia
Química orgánica
Chemistry, Organic
Versión del editor
Aparece en las colecciones